Comparative Analysis of “ Screening vs Modified ” APTT based activated protein C resistance (APCR) assay in the diagnosis of Factor V leiden mutation


Original Article

Author Details : Mirza Asif Baig*

Volume : 5, Issue : 1, Year : 2020

Article Page : 48-52

https://doi.org/10.18231/j.jdpo.2020.010



Suggest article by email

Get Permission

Abstract

Introduction: APCR is a hemostatic disorder characterized by increased risk of deep vein thrombosis and
pulmonary embolism. Factor V Leiden mutation accounts for 95% of APCR cases & the remainder are due
to acquired causes like patients on vitamin k antagonist therapy, direct oral acting anticoagulants, Lupus
anticoagulant & oral contraceptive pills. T he main objective of this study is to compare the sensitivity of
APTT based APCR test vs Modified APTT with pre -dilution in F actor V-deficient plasma for diagnosis
of Factor V leiden mutation & to formulate a systematic diagnostic algorithm for interpretation of APCR
tests.
Materials and Methods: The Coagulometer used for APCR test is Sysmex CS-5100. APTT reagent used
is Pathrombin SL supplied by seimens. All data were expressed as Mean SD. Statistical analysis was
done using unpaired students t test & a P value <0> Results: A total of 150 cases of APCR (100 cases of factor V Leiden mutation confirmed by PCR &
50 non carrier /acquired cases) were studied retrospectively. Sensitivity of screening APTT base d APCR
for detection of factor V Leiden mutation is 78% & for non carrier state it is 82%. Sensitivity of modified
APTT with pre- dilution in FV-deficient plasmafor detection of factor V Leiden mutation is 93% & for
noncarrier state (acquired) is 34%.
Conclusion: Screening APTT test is increased in Activated protein C resistance due to factor V Leiden
mutation as well as acquired causes like patients on direct acting oral anticoagulants, warfarin, lupus
anticoagulants and oral contraceptive pills which are independent risk factors of venous thrombosis.
Modified APTT with predilution in FV-deficient plasma (1:4) is more sensitive than Screening APTT based
APCR test in diagnosis of Factor VLeiden mutation&this test can distinguish homozygous&heterozygous
states from normal individuals.

Keywords: APTT, Activated Protein C resistance factor V Leiden mutation LAC


How to cite : Baig M A, Comparative Analysis of “ Screening vs Modified ” APTT based activated protein C resistance (APCR) assay in the diagnosis of Factor V leiden mutation. IP J Diagn Pathol Oncol 2020;5(1):48-52


This is an Open Access (OA) journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.







View Article

PDF File   Full Text Article


Copyright permission

Get article permission for commercial use

Downlaod

PDF File   XML File  


Digital Object Identifier (DOI)

Article DOI

https://doi.org/10.18231/j.jdpo.2020.010


Article Metrics






Article Access statistics

Viewed: 1902

PDF Downloaded: 561



Medical Abbreviation List